Okay, so I had this all written, and my browser crashed and lost it. So here is the "I'm frustrated with this" quick version.
I finished putting my fan shroud together last night. I've had these fans for a couple years, and they work fine. If I hook them up backward, they run backward. They are 1995 Mercedes C280 fans, hooked in parallel from the factory, with factory connections except where I cut the wires.
The wires end right at the edge of that picture.
I have a hot wire running from the battery cable on the starter, just for doing engine test runs, and test driving. I have a maintenance charger on the battery.
I put my fan shroud together last night, and tested the fans in reverse and forward, to see where and how the air moves, now that I have a proper shroud on it. It worked great. Water was running downhill, fire was hot, and the IRS still wants more than their share.
Rather than have a hot wire laying loose, I hooked the hot supply to the fan hot, and grounded the negative to run the fans. I used to have the ground wire under a screw on the fan shroud, and connect the hot wire to run them, but I accidentally shorted it to the frame once, and so that's why I switched the connection.
So I'm planning on wiring the fans with a relay and such, and from what I've seen on other fan systems, and one I have on my 59, the fans have constant power, and a switched ground to run. Right now, it's just hot to hot, and touch the wire to ground to run.
I walked out this morning to go to work, and heard my fans running. I went back behind the garage, and sure enough, my fans are running, with no ground! I took a quick video without touching it first.
http://youtu.be/GZDC21_oP48
I had to get to work, so I didn't have time to investigate.
What is going on here?
I finished putting my fan shroud together last night. I've had these fans for a couple years, and they work fine. If I hook them up backward, they run backward. They are 1995 Mercedes C280 fans, hooked in parallel from the factory, with factory connections except where I cut the wires.

The wires end right at the edge of that picture.
I have a hot wire running from the battery cable on the starter, just for doing engine test runs, and test driving. I have a maintenance charger on the battery.
I put my fan shroud together last night, and tested the fans in reverse and forward, to see where and how the air moves, now that I have a proper shroud on it. It worked great. Water was running downhill, fire was hot, and the IRS still wants more than their share.
Rather than have a hot wire laying loose, I hooked the hot supply to the fan hot, and grounded the negative to run the fans. I used to have the ground wire under a screw on the fan shroud, and connect the hot wire to run them, but I accidentally shorted it to the frame once, and so that's why I switched the connection.
So I'm planning on wiring the fans with a relay and such, and from what I've seen on other fan systems, and one I have on my 59, the fans have constant power, and a switched ground to run. Right now, it's just hot to hot, and touch the wire to ground to run.
I walked out this morning to go to work, and heard my fans running. I went back behind the garage, and sure enough, my fans are running, with no ground! I took a quick video without touching it first.
http://youtu.be/GZDC21_oP48
I had to get to work, so I didn't have time to investigate.
What is going on here?